E-CLAT- VS400
ELECTROSURGICAL UNIT
e-clat- vs400
We introduce the most versatile Electro Surgical generator in the form of E-CLAT- VS400. As compared to a single generator, it offers some exceptional features and excellent performance in microsurgery, neurosurgery, laparoscopy and other surgeries. It features a unique spray coagulation mechanism integrated into it that ensures minimum cutting effect. In this equipment, isolated bipolar output has non sparking characteristic and pure cut starts automatically even in irrigated surgical procedures.
- Provides Good Hemostasis Effect
- Feedback-controlled Response System
- Automatically Stops Energy Delivery As Soon As The Seal Cycle Is Complete
- Spray Coagulation
- Minimum Cutting Effect
Specifications
- Program Mode:
- 25 User Settable Program Mode
- Frequency:
- 500Khz
- Display:
- 7 Segment Led
- Weight:
- 4.5Kg (Approx)
- Dimension:
- 405Mm(L) X 340Mm(W) X 145Mm(H)Input Supply Voltage 230V (+ / – 15%) 50Hz
- Voltage:
- Input Supply Voltage 230V (+ / – 15%) 50Hz
Cut :
Pure cut : It produces a high-frequency alternating current for smooth, rapid cuts with little or no hemostasis
Blend 1 : This mode offers varying degrees of hemostasis to surgeon in cut mode
Blend 2 : The mode helps in vaporization of prostatic tissue or any fat tissue. The high wattage output offers fast cutting of tissues
Endo cut : The automatic cut system is used for the reduction in complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST in comparison with the conventional blended cut mode.
Coag :
- Force : The Force mode covers the demands of standard coagulation by producing fine waveform that creates superficial resistance in the tissue resulting in superior coagulation, where the tissue destroyed by hyper evaporation. This enable surgeons for the removal of surface structures without damaging deep or peripheral tissues and to cauterize large surface areas quickly when required.
- Spray : The mode supports direct coagulation at tissue with spark. The CREST FACTOR is high thus not giving any cutting effect to the tissue.
- Fulgurate : It raises the voltage to produce a spark between electrodes for the coagulation of tissue. There is no contact between tissue and electrode.
- Desiccate : This Coagulation in which electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries. It ensures pinpoint desiccation with less destruction of peripheral tissue
Bipolar :
- Micro : High Voltage force coagulation for special purpose when speed is required.
- Macro : For highly precise control over coagulation process and privations of carbonization.
- Cut : This Bipolar CUT technology nearly eliminate excessive current, even during precision cutting in minute SAFETY FEATURES tissue structure.
- Auto : Coagulation start by pressing the footswitch and stops output and audio signal automatically when the tissue is coagulated.
Vessel Seal :
- Across the range, Vessel Sealing technology delivers a unique combination of pressure and energy to create a consistent seal with each application :-
- Shorter operating time – save almost upto 75% operating time.
- Permanently fuses vessels upto and including 7 mm diameter and tissue bundles without desiccation or isolation.
- Faster and safer patient recovery.
- Seals withstand 3 times normal systolic blood pressure.
- Uses bodies own collagen, no requirement to insert foreign material into patient body which can cause complications.
- Feedback controlled response system automatically discontinues energy delivery when the seal is complete, eliminating the guess work.